Workflows / LOD 400 services: ducts, pipes, trays and their parts
LOD 400 services: ducts, pipes, trays and their parts
Building services from LOD 300 to LOD 400 in one Calq model: runs routed, sized and connected with their fittings, valves, dampers and insulation, sleeves through every wall and slab, hangers and riser clamps from the structure, and the runs cut into the parts a shop makes.
- Available
What LOD 400 asks of the services
For ductwork, pipework and containment, LOD 400 is what a fabrication shop and an installer need: every straight cut to the length the shop makes, every fitting a part with its number, every hanger at its place with what it hangs from, every sleeve through every wall and slab. It stands on an LOD 350 model where the runs are already clear of the structure and of each other.
In Calq the runs are typed by system and connected to what they serve through real ports, so the parts, the hangers and the sleeves are read from the runs and follow them when they move.
Before LOD 400: routed, sized and coordinated
- Lay the systems: the Building services (MEP) shelf, Duct, Pipe, Cable tray, Conduit, Terminal, Equipment, Fixture, Sprinkler, Light, Device, Panel. Or ask Calq AI "serve every flat with cold and hot water and waste, and route supply and extract air from the plant room" (create_services, serve_plant, route_services, place_terminals, generate_layout).
- Size them from the flows: size_services and calculate_services, with a riser schematic (services_schematic) and the readout of every system (services_readout).
- Give each run its type: material, joint and elbow radius; its insulation at the thickness you set and its lining; its fall on drainage (edit_runs, set_service_system; the shelf's Insulate, Lining, Slope).
- Fittings are solids: elbows, tees, crosses, reducers, transitions and caps; accessories in the run: isolating, check and pressure reducing valves, strainers, drain cocks, meters, volume, fire and smoke dampers, attenuators (the shelf's Accessory).
- Circuits and panels for power and lighting (set_circuits, panel_schedule).
- Clear the clashes: the shelf's Coordinate and Fix clashes, or coordinate_model and fix_clashes: the services moved clear of the structure and of each other, by the coordination priority.
LOD 350: sleeves and hangers
- Every run that crosses a wall or a slab gets a real opening with its sleeve, written to IFC as an opening and a sleeving covering; across linked models the owner of the wall makes the hole (coordinate_model, coordinate_links, create_voids).
- Hangers are laid on every level run and riser from where the structure stands: trapezes under trays and ducts, clevis hangers round small pipes, a riser clamp at every slab, each dropped from the slab or beam over it (set_supports; Properties, Supports).
- Read the support schedule: each hanger's run, kind, what it hangs from, its drop and the spacing it was laid at, and the runs left unhung with the reason (support_schedule). Hangers are written to IFC as IfcDiscreteAccessory.
- Stand plant that turns on vibration isolators: four under each pump, fan, chiller, air handler or boiler, of the kind you or your engineer name, written to IFC as IfcVibrationIsolator (mount_on_isolators).
LOD 400: the parts a shop makes
- Select runs and press Fabricate on the shelf or in the selection bar's More menu, or ask Calq AI "cut the ductwork of level 3 into fabrication parts" (fabrication_schedule).
- Every straight is cut into stock lengths (the type's, a common catalogue length said as assumed, or the run's own), the last cut to what is left; every fitting is a part; each part gets its item number by system in run order.
- Read and export the fabrication schedule: the parts by run with their sizes, lengths and numbers, as a schedule on a sheet or a spreadsheet (the fabrication schedule plate, export_schedule).
- Lifts, escalators and moving walks are placed with their shafts, pits, cars and doors by their standards (place_lift, place_lift_cars).
- Bring the services to LOD 400 in one step from what the model holds: sizes taken to the table of each system, dead ends capped, isolating valves on water and heating branches (assumed and said), fire dampers where a wall type states a rating, circuits, and every run cut into fabrication parts; then read the LOD of each section (make_mep_lod, mep_lod).
- Spools: the pipework is broken into spools at every wall and slab it crosses, each with its numbered parts and an isometric; they leave as a Piping Component File for a pipe shop and as a spool list (export_exchange, pcf and spools).
What leaves the model
- IFC with every segment, fitting, valve, damper, terminal and piece of equipment in its class, the ports that connect them and their systems, insulation and sleeves as coverings, hangers as discrete accessories
- The MEP schedules, the panel schedules, the support schedule and the fabrication schedule (mep_schedule, panel_schedule, support_schedule, fabrication_schedule)
- BCF issues for every clash a person must decide (clash_issues)
Questions
Does Calq lay hangers automatically?
Yes. Hangers and riser clamps are laid on every run from where the structure stands, at the spacing you give, and the support schedule lists them and the runs left unhung.
Can Calq cut ductwork into fabrication parts?
Yes. Fabricate cuts each straight into stock lengths and numbers every straight and fitting as a part, and the fabrication schedule lists them.
Are sleeves modelled through walls and slabs?
Yes. Each crossing gets a real opening and a sleeve, written to IFC, and a linked model's crossings are asked of the owner of the wall.