Workflows / MEP modelling in the BIM model
MEP modelling in the BIM model
Model building services in the same BIM model as the architecture and the structure: ducts, pipes, cable trays and conduits, connected to their terminals and equipment, with fittings, circuits, schedules and IFC.
- Available
- Free account
What it is
Services in Calq are connected systems, not coloured lines. Every run carries its system, such as supply air, cold water, waste or power, and every run, terminal and piece of equipment has typed connectors. A run end on a connector is joined to it: move the equipment and the run follows.
The services are in the same model as the walls, slabs and beams, so they are drawn in the same plans and sections and checked against the building they run through.
What you model
- Air: ducts and flex ducts, diffusers, grilles, extract fans, air handling units and fan coils, with duct linings
- Water and heating: pipes, boilers, pumps, tanks and radiators
- Drainage: sanitary fixtures, waste runs that keep their fall, and soil stacks with their vent on the roof and the inspection chamber where the drain leaves
- Fire: sprinkler heads and hose reels on their pipes
- Electrical: cable trays and conduits, sockets, switches, data outlets, lights and distribution boards
- Circuits dealt to a board, with its panel schedule
What Calq does for you
- Fittings are laid by rule wherever runs meet: an elbow, a reducer or a transition, a tee, a cross, a cap. A run moved carries its fittings.
- Sizes snap to the standard size table of the run's system, and a drain keeps its gradient when it is moved in plan
- Where a run crosses a wall or a slab, a sleeve and an opening are laid in the host
- A whole room, a flat or the communal plant can be served in one step, and a run can be routed several ways to compare as options
- Heat loss room by room, flows and sizes are worked out from the building, each figure with its source, and an assumption said as assumed
Coordination
A clash report reads every run and fitting against beams, columns, slabs, walls and footings, for hard clashes and clearances, and a run in a room with a ceiling is checked against the ceiling void.
Each clash becomes a BCF issue with its two elements and a viewpoint, so it travels to the other trades' tools as a .bcfzip and comes back. An issue whose clash is gone is marked resolved.
What you get
- Services plans and sections where every run says its size and its system
- A riser schematic read from the model: the storeys, every riser and stack, and what each system feeds on each storey
- Schedules of runs, fittings, equipment and panels, and a fabrication schedule of numbered parts
- IFC with distribution systems, ports and their connections, segments, fittings, terminals, equipment and circuits
Good to know
MEP modelling, its drawings, schedules and IFC export are on the Free account. Calq AI, on the paid plans, serves rooms and routes services when asked in words.
Calq lays and coordinates the services; the design is the engineer's. A size, a flow or a fall is a read figure of a named source or your own, and the calculations are a first reading for the engineer to check, with every assumption said.
Questions
Can I model MEP in the browser?
Yes. Calq models ducts, pipes, cable trays, conduits, terminals and equipment in the browser, in the same BIM model as the architecture and the structure, on the Free account.
Are the services connected, or only drawn?
Connected. Every run, terminal and piece of equipment has typed connectors, a run end joins the connector it stands on, and the fittings are laid by rule where runs meet. The connections are written to IFC as ports.
Does Calq find clashes between services and structure?
Yes. The clash report reads every run and fitting against beams, columns, slabs, walls and footings, and each clash can travel as a BCF issue.
Can I make a panel schedule?
Yes. The devices of a board are dealt into circuits, and the board's panel schedule is read from the model. A load Calq assumes is said as assumed.
Do the services export to IFC?
Yes. Runs, fittings, terminals and equipment are written with their IFC classes, grouped in distribution systems and joined by their ports, with sleeves and openings where a run crosses a wall or a slab.