Workflows / LOD 300: every element as designed, measurable
LOD 300: every element as designed, measurable
LOD 300 step by step: each element at its true size, shape, place and orientation, with its type, build-up, material and IFC class, and how Calq turns a scheme into a measurable design model with its drawings, schedules and IFC.
- Available
- Free account
What LOD 300 means
At LOD 300 an element is modelled as designed. Its quantity, its size, its shape, its place and its orientation can be measured from the model and relied on, and it is placed in the project's own coordinates. It conveys the design intent completely for that element.
LOD 300 is where most designers' models stop, and where the tender drawings come from. It is not necessarily free of clashes: an element is at its true size so that the space it needs is known, and resolving every interface is the work of LOD 350.
What each trade looks like at LOD 300
- Architecture: walls, floors, roofs and ceilings with their layers and thicknesses; doors and windows of their real types and sizes; stairs with their risers, goings and landings; rooms with their finishes
- Structure: every column, beam, brace, slab, wall and foundation at its section, depth and material, on the grid and at its level; openings that need formwork; slopes
- Services: ducts, pipes, trays and conduits at their size and in their system, connected to their terminals and equipment; plant at its size; the main valves and dampers
- Site: the graded ground, kerbs, paving and paths at their levels, the drainage runs, the planting areas
Build it in Calq, step by step
- Give every element its type: select it and change its type in Properties, or ask Calq AI "make every external wall the 300 mm brick and block cavity wall" (set_types, edit_elements). The element keeps its id, its place and its openings.
- Set the build-ups: a wall, floor or roof type is a set of layers, each a material and a thickness, with its function; its thermal figures and fire rating are read from those layers and from the type's own properties.
- Size the structure: the members on the grid with their sections by name, the foundations under them. Calq lays and keeps them connected: a column on a grid crossing moves with the grid, a beam follows what it frames to, a pad stays under its column. The sizes are the engineer's: a default is a placeholder and says so.
- Route and size the services: route_services lays the runs, size_services sizes them from the flows you give, calculate_services reads the loads; every run is connected to what it serves.
- Lay the site: the Site shelf for the ground, paths, paving and the plot's enclosure when you ask for it (build_topography, enclose_plot).
- Draw it: plans, sections, elevations, schedules and sheets are read from the model, dimensioned by the one engine and tagged by the one tag look (make_sheet, dimension_plan, export_drawing).
Check LOD 300 before an issue
- Every element typed: a schedule of untyped elements is empty (get_schedule)
- The information each element must carry at this stage: check_ids against the project's IDS file
- The model's faults and the building code: check_model, and the Project menu, Check, Code check
- A first clash pass, to know what LOD 350 will have to resolve: coordination_report
- The IFC opened in another viewer: the element classes, the types, the layers and the quantities are what the receiver expects (export_ifc)
Moving to LOD 350
Find where elements meet and model the meeting: the openings each run needs through each wall and slab, the hangers and supports, the connections, the clearances for access and maintenance. Calq does most of that from what the model already holds; the next page shows how.
Questions
Does LOD 300 mean the model is clash free?
No. At LOD 300 elements are at their true size so the space they need is known. Resolving the interfaces between trades is LOD 350.
Are tender drawings LOD 300?
Usually. Plans, sections, elevations and schedules read from an LOD 300 model describe the design completely; the makers then develop their parts to LOD 350 and 400.
Does Calq size the structure and the services?
Calq sizes ducts and pipes from the flows you give and checks members against the loads you give, and says each figure's source. A structural design remains the engineer's: a default section is a placeholder and is said to be one.
Can I change a type later without redrawing?
Yes. An element keeps its id, its place, its hosted openings and its links when its type changes, and every drawing, schedule and export follows.