Workflows / Envelope check against the energy code
Envelope check against the energy code
Calq works out the U-value of every wall, roof, floor, window and door type from the model's own layers and holds the envelope to the energy code of the model's country, part by part, and exports gbXML for energy analysis.
- Available
What it is
The envelope of a Calq model is read by one reader. It finds the walls that face outside, the roofs, the ground floors, the windows and the outside doors, groups them by type, and gives each type its U-value from its build-up, layer by layer.
Where the building code set on the model holds envelope limits, each type answers to the limit of its part for the climate zone of the site. The result is a table you can read on the board and print as the energy page of the permit set.
How it goes
- Give the wall, roof and floor types their layers and materials; a material carries its conductivity
- Give window and door types the U-value their maker states
- Set the building code and the site's address: the climate zone is read from the place, or you name it
- Run the check: every type with its build-up, its U-value, the limit and whether it meets it
- Change a layer or a type and run it again
What you get
- The U-value of each envelope type, worked out from the model's layers and area-weighted per part
- The limit of each part with its clause and its source, where the code's data holds one
- The glazed share of the external walls
- A list of what the code asks and the model gives no way to measure, said as not measured
- The energy page of the permit set, in the model's language
- gbXML 0.37 with second-level space boundaries, checked against the official schema, for an energy analysis tool
The limits Calq holds
For Saudi Arabia Calq holds the envelope table of SBC 602 for climate zones 1 to 3, read in official guides and marked as such on every figure. A limit the guides do not agree on is not held.
With a code that holds no energy figures, Calq gives the U-values and judges nothing. A limit is never borrowed from another country's code.
Good to know
It is a pre-check of the envelope, never a certificate and not an energy simulation: loads and consumption are worked out in an energy analysis tool, which reads the gbXML or the IFC that Calq exports.
A part with no limit held, or with no U-value because a type or a conductivity is missing, is never counted as a pass. A default is never used as a U-value.
gbXML and IFC export are on the free account. The check against the energy code is part of Studio's code check: calq.live/pricing says what it holds.
Questions
Can Calq calculate the U-value of a wall?
Yes. The U-value of a wall, roof or floor type is worked out from its layers and the conductivity of their materials. A window or a door takes the U-value its type states.
Does Calq check a building against the energy code?
Yes, where Calq holds the code's envelope limits: each wall, roof, floor, window and door type is held to the limit of its part for the site's climate zone. Today that is Saudi Arabia's SBC 602.
Can I export gbXML from Calq?
Yes. Calq exports gbXML 0.37 with second-level space boundaries from the browser, on the free account.
Is this an energy simulation?
No. Calq checks the envelope against the code's limits. For loads and consumption, the model goes to an energy analysis tool as gbXML or IFC.
What happens when the code has no limit for a part?
Calq says the limit is not held and gives the U-value alone. Not held and not measured are never shown as a pass.